Diagnostic Test
- CHECK HAZARD SWITCH SIGNAL BY CONSULT
With CONSULT
- Turn ignition switch ON.
- Select "FLASHER" of "BCM" using CONSULT.
- Select "HAZARD SW" in "Data Monitor" mode.
- With operating the hazard switch, check the monitor status.
Monitor item Condition Monitor status HAZARD SW Hazard switch ON On OFF Off
Is the inspection result normal?
YES
Hazard switch circuit is normal.
NO
Refer to DIAGNOSIS PROCEDURE .