Diagnosis Procedure
- CHECK TRUNK LID OPENER REQUEST SWITCH OUTPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect trunk lid opener request switch assembly connector.
- Check signal between trunk lid opener request switch assembly harness connector and ground using oscilloscope.
(+) (-) Signal
(Reference value)Trunk lid opener request switch assembly Connector Terminal T47 1 Ground
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and trunk lid opener request switch assembly harness connector.
BCM Trunk lid opener request switch assembly Continuity Connector Terminal Connector Terminal M15 83 T47 1 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M15 83 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK TRUNK LID OPENER REQUEST SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener request switch assembly harness connector and ground.
Trunk lid opener request switch assembly Ground Continuity Connector Terminal T47 2 Existed Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK TRUNK LID OPENER REQUEST SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Replace trunk lid opener request switch.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END