Component Inspection
- CHECK TRUNK LID OPENER CANCEL SWITCH
- Turn ignition switch OFF.
- Disconnect trunk lid opener cancel switch connector.
- Check continuity between trunk lid opener cancel switch terminal.
Trunk lid opener cancel switch Condition Continuity Terminal 1 2 Trunk lid opener cancel switch Set ON Existed Set OFF Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace trunk lid opener cancel switch.