Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- CHECK SUB ELECTRIC OIL PUMP RELAY
- Disconnect sub electric oil pump relay. Refer to COMPONENT LOCATION .
- Apply 12V direct current between sub electric oil pump relay terminals 1 and 2.CAUTION:
- Never make the terminals short.
- Connect the fuse between the terminals when applying the voltage.
- Check continuity between sub electric oil pump relay terminals 3 and 5.
Sub electric oil pump relay Condition Continuity Terminal 3 - 5 Apply 12 V direct current between terminals 1 and 2. Existed Does not apply 12 V direct current between terminals 1 and 2. Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace sub electric oil pump relay.