Diagnosis Procedure
- CHECK BCM SIGNAL 1
- Turn ignition switch OFF.
- Disconnect remote keyless entry receiver connector.
- Check voltage between remote keyless entry receiver harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Remote keyless entry receiver Connector Terminal B20 1 Ground 5
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLYCIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M71 110 B20 1 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M71 110 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
- Reconnect remote keyless entry receiver connector.
- Check signal between remote keyless entry receiver harness connector and ground using oscilloscope.
(+) (-) Voltage (V)
(Approx.)Remote keyless entry receiver Connector Terminal B20 1 Ground
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Replace remote keyless entry receiver.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
- Disconnect BCM connector and remote keyless entry receiver connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M68 18 B20 4 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M68 18 Not existed
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace harness.
- CHECK BCM SIGNAL 2
- Reconnect BCM connector.
- Check voltage between remote keyless entry receiver harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Remote keyless entry receiver Connector Terminal B20 3 Ground 5
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
GO TO STEP 6 .
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M71 71 B20 3 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M71 71 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL
- Reconnect remote keyless entry receiver connector.
- Check signal between remote keyless entry receiver harness connector and ground using oscilloscope.
(+) (-) Condition Signal
(Reference value)Remote keyless entry receiver Connector Terminal B20 3 Ground Waiting Press the Intelligent Key lock or unlock button
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Replace remote keyless entry receiver.
- CHECK BCM SIGNAL 3
- Disconnect remote keyless entry receiver connector.
- Check voltage between remote keyless entry receiver harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Remote keyless entry receiver Connector Terminal B20 2 Ground 5
Is the inspection result normal?
YES
GO TO STEP 10 .
NO
GO TO STEP 9 .
- CHECK REMOTE KEYLESS ENTRY RECEIVER RSSI CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M68 22 B20 2 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M68 22 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER RSSI OUTPUT SIGNAL
- Reconnect remote keyless entry receiver connector.
- Check signal between remote keyless entry receiver harness connector and ground using oscilloscope.
(+) (-) Condition Signal
(Reference value)Remote keyless entry receiver Connector Terminal B20 2 Ground Waiting Press and hold Intelligent Key lock or unlock button
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
Replace remote keyless entry receiver.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END