Diagnosis Procedure
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B26 22 Existed Is the inspection result normal?
YES
Replace automatic back door control module. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.