Diagnosis Procedure
- CHECK HALF LATCH SWITCH SIGNAL
- Select "AUTOMATIC BACK DOOR CONTROL UNIT" using CONSULT.
- Select "HALF LATCH SW" in "DATA MONITOR" mode.
- Check that the function operates normally according to the following conditions.
Monitor item Condition Status HALF LATCH SW Back door Fully closed/Half latch OFF Open ON Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 2 .
- CHECK HALF LATCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect back door lock assembly connector.
- Check voltage between back door lock assembly harness connector and ground.
(+) (-) Voltage
(Approx.)Back door lock assembly Connector Terminal D157 6 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- CHECK HALF LATCH SWITCH CIRCUIT
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and back door lock assembly harness connector.
Automatic back door control module Back door lock assembly Continuity Connector Terminal Connector Terminal B26 8 D157 6 Existed
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK HALF LATCH SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Back door lock assembly Ground Continuity Connector Terminal D157 8 Existed Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace back door lock assembly ground circuit.
- CHECK HALF LATCH SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Replace back door lock assembly.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END