Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
Power source Fuse No. Ignition switch ON or START 4 Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check voltage between sonar control unit harness connector and ground.
Sonar control unit Ground Voltage
(Approx.)Connector Terminal M47 13 Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace sonar control unit power supply harness.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect sonar control unit connector.
- Check continuity between sonar control unit harness connector and ground.
Sonar control unit Ground Continuity Connector Terminal M47 24 Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace sonar control unit ground harness.