Diagnosis Procedure
- CHECK INPUT 1 - 5 CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect BCM and combination switch connectors.
- Check continuity between BCM harness connector and combination switch harness connector.
System BCM Combination switch Continuity Connector Terminal Connector Terminal INPUT 1 M68 6 M27 12 Existed INPUT 2 5 14 INPUT 3 4 5 INPUT 4 3 2 INPUT 5 2 8
Does continuity exist?
YES
GO TO STEP 2.
NO
Repair harnesses or connectors.
- CHECK INPUT 1 - 5 CIRCUIT FOR SHORT
Check for continuity between BCM harness connector and ground.
System BCM Ground Continuity Connector Terminal INPUT 1 M68 6 Not existed INPUT 2 5 INPUT 3 4 INPUT 4 3 INPUT 5 2 Does continuity exist?
YES
Repair harnesses or connectors.
NO
GO TO STEP 3.
- CHECK BCM INPUT SIGNAL
- Connect BCM and combination switch connectors.
- Turn ON any switch in the system that is malfunction.
- Check voltage between BCM harness connector and ground.
System Terminals Voltage
(Approx.)(+) (-) BCM Ground Connector Terminal INPUT 1 M68 6 Refer to REFERENCE VALUE . INPUT 2 5 INPUT 3 4 INPUT 4 3 INPUT 5 2
Is the measurement value normal?
Yes
Replace BCM. Refer to REMOVAL AND INSTALLATION .
No
Replace combination switch.