LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 40 (Engine Control System (DTC/Circuit Diagnosis) (VQ35DE) (Except Hybrid) (1 Of 3)) >> DTC/Circuit Diagnosis >> DTC P0030, P0031, P0032, P0036, P0051, P0052: A/F Sensor 1 Heater >> DTC Logic >> DTC Detection Logic

DTC Detection Logic

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
DTC No. CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition Possible cause
P0030 A/F SEN1 HTR (B1)
(HO2S heater control circuit bank 1 sensor 1)
Deterioration in A/F sensor 1 heater performance.
(Voltage signal transmitted from A/F sensor 1 heater to ECM is higher/lower than voltage in the normal range.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is open or shorted.)

  • A/F sensor 1 heater
P0031 A/F SEN1 HTR (B1)
(HO2S heater control circuit low bank 1 sensor 1)
The current amperage in the A/F sensor 1 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the A/F sensor 1 heater.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is open or shorted.)

  • A/F sensor 1 heater
P0032 A/F SEN1 HTR (B1)
(HO2S heater control circuit high bank 1 sensor 1)
The current amperage in the A/F sensor 1 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the A/F sensor 1 heater.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is shorted.)

  • A/F sensor 1 heater
P0036 A/F SEN1 HTR (B2)
(HO2S heater control circuit bank 2 sensor 1)
Deterioration in A/F sensor 1 heater performance.
(Voltage signal transmitted from A/F sensor 1 heater to ECM is higher/lower than voltage in the normal range.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is open or shorted.)

  • A/F sensor 1 heater
P0051 A/F SEN1 HTR (B2)
(HO2S heater control circuit low bank 2 sensor 1)
The current amperage in the A/F sensor 1 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the A/F sensor 1 heater.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is open or shorted.)

  • A/F sensor 1 heater
P0052 A/F SEN1 HTR (B2)
(HO2S heater control circuit high bank 2 sensor 1)
The current amperage in the A/F sensor 1 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the A/F sensor 1 heater.)
  • Harness or connectors

    (The A/F sensor 1 heater circuit is shorted.)

  • A/F sensor 1 heater