Diagnosis Procedure
WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK STARTER RELAY
- Turn ignition switch ON.
- Check voltage between BCM harness connector and ground under the following condition.
BCM Ground Condition Voltage (V) Connector Terminal M19 62 Ground Ignition switch cranking 0 Ignition switch ON (Park or Neutral) Battery voltage Other than above 0
Is the measurement value within the specification.
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK STARTER RELAY CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM harness connector and IPDM E/R harness connector.
- Check continuity between IPDM E/R harness connector and BCM harness connector.
IPDM E/R BCM Continuity Connector Terminal Connector Terminal E119 33 M19 62 Yes - Check continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E119 33 Ground No
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair harness or connector.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Inspection End.