Diagnosis Procedure
WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK CVT SHIFT SELECTOR SWITCH FUNCTION
- Turn ignition switch ON.
- Select "SFT PN-IPDM" and "SFT PN/N SW" in DATA MONITOR mode with CONSULT.
- Check "SFT PN-IPDM" and "SFT PN/N SW" indication under the following conditions.
Monitor item Condition Indication SFT PN-IPDM CVT Shift selector Any position other than P (Park) or N (Neutral) position OFF P (Park) or N (Neutral) position ON SFT PN/N SW CVT Shift selector Any position other than P (Park) or N (Neutral) position OFF P (Park) or N (Neutral) position ON
Is the inspection result normal?
YES
Refer to INTERMITTENT INCIDENT .
NO-1
If SFT PN-IPDM is incorrect. GO TO 2.
NO-2
If SFT PN/N SW is incorrect. GO TO 5.
- CHECK IPDM E/R INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Turn ignition switch ON.
- Check voltage between IPDM E/R harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)IPDM E/R Connector Terminal F24 66 Ground Selector lever P (Park) or N (Neutral) position 12 Other than above 0
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 3 .
- CHECK IPDM E/R INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Check continuity between IPDM E/R harness connector and transmission range switch harness connector.
IPDM E/R Transmission range switch Continuity Connector Terminal Connector Terminal E119 37 F29 10 Yes - Check continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E119 37 No
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- REPLACE IPDM E/R
- Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
Inspection End.
- CHECK BCM INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between BCM harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)BCM Connector Terminal M18 39 Ground Selector lever P (Park) or N (Neutral) position 12 Other than above 0
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 7 .
- REPLACE BCM
- Replace BCM. Refer to REMOVAL AND INSTALLATION .
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
Inspection End.
- CHECK BCM INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect transmission range switch connector.
- Disconnect BCM connector.
- Check continuity between transmission range switch harness connector and BCM harness connector.
Transmission range switch BCM Continuity Connector Terminal Connector Terminal F29 10 M18 39 Yes - Check continuity between transmission range switch harness connector and ground.
Transmission range switch Ground Continuity Connector Terminal F29 10 No
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .