Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 35 (Intelligent Cruise Control System (Introduction, Wiring Diagrams And Basic Inspection) (ICC) (Except Hybrid)) >> Basic Inspection >> ICC Sensor Alignment >> Description >> Cautionary Point For ICC Sensor Alignment Procedure

Cautionary Point For ICC Sensor Alignment Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
  • For radar alignment procedure, choose a level location with a few feet of working space in front and surrounding the vehicle.
  • Vehicle must be stationary and unoccupied during the whole alignment procedure.
  • Any slight vibration during the alignment procedure can cause the test to fail. If this happens, you will have to restart the alignment process.
  • The battery voltage must not fall below 12 volts during the whole alignment procedure. Failure to maintain adequate battery voltage will cause the test to fail. If this happens, you will have to restart the alignment process.
  • The ICC target board must be set in front of the vehicle facing the sensor.
  • Adjust the ICC sensor alignment with CONSULT. (The ICC sensor alignment procedure cannot be adjusted without CONSULT.)
  • Never enter the vehicle during ICC sensor alignment.
  • Never block the area between the ICC sensor and the ICC target board at any time during the alignment process.
  • Accurate steering wheel setting is crucial. Once set, do not disturb the steering wheel for the remainder of the alignment procedure.
  • For proper system operation and adjustment, all vehicle wheels must be of the same size.