LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 25 (Starting System (Except Hybrid)) >> DTC/Circuit Diagnosis >> S Connector Circuit >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

CAUTION:

Perform diagnosis under the condition that engine cannot start by the following procedure.

  1. Remove fuel pump fuse.
  2. Crank or start the engine (where possible) until the fuel pressure is released.

  1. CHECK STARTER MOTOR MAGNETIC SWITCH CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect starter motor connector F28.
    3. Shift transmission into park or neutral.
    4. Check voltage between starter motor connector F28 terminal S and ground with the ignition in START.
      (+) (-) Condition Voltage
      (Approx.)
      Connector Terminal
      F28 S Ground Ignition switch in START position Battery voltage

    Is the inspection result normal?

    YES 

    Magnetic switch circuit is OK. Further inspection is necessary. Refer to WORK FLOW (WITH GR8-1200 NI)  or WORK FLOW (WITHOUT GR8-1200 NI) .

    NO 

    GO TO STEP 2 

  2. CHECK CONNECTOR

    1. Turn ignition switch OFF.
    2. Check the IPDM E/R connector F17 and starter motor connector F28 for damage, bent pins and loose connections.

    Is the inspection result normal?

    YES 

    GO TO STEP 3 

    NO 

    Repair the terminal and connector.

  3. CHECK HARNESS CONTINUITY (OPEN CIRCUIT)

    1. Disconnect IPDM E/R connector F17.
    2. Check continuity between starter motor connector F28 terminal S and IPDM E/R connector F17 terminal 51.
      Connector Terminal Connector Terminal Continuity
      F28 S F17 51 Yes
    3. Check continuity between starter motor connector F28 terminal S and ground.
      Connector Terminal - Continuity
      F28 S Ground No

    Is the inspection result normal?

    YES 

    Further inspection is necessary. Refer to WORK FLOW (WITH GR8-1200 NI)  or WORK FLOW (WITHOUT GR8-1200 NI) .

    NO 

    Repair the harness.