Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FUSE
- Turn ignition switch OFF.
- Check 10A fuse [No. 30, located in fuse block (J/B)].NOTE:
Refer to TERMINAL ARRANGEMENT .
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Replace the blown fuse after repairing the affected circuit.
- CHECK IONIZER POWER SUPPLY
- Disconnect ionizer connector.
- Turn ignition switch ON.
- Check voltage between ionizer harness connector and ground.
+ - Voltage
(Approx.)Ionizer Connector Terminal M119 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair harness or connector between ionizer and fuse block (J/B).
- CHECK IONIZER GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between ionizer harness connector and ground.
Ionizer - Continuity Connector Terminal M119 3 Ground Yes
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair harness or connector.
- CHECK IONIZER (ON/OFF) CONTROL SIGNAL CIRCUIT
- Connect ionizer connector.
- Disconnect A/C auto amp. connector.
- Turn ignition switch ON.
- Check voltage between A/C auto amp. harness connector and ground.
+ - Voltage
(Approx.)A/C auto amp. Connector Terminal M50 38 Ground Battery voltage
Is the inspection result normal?
YES
Replace A/C auto amp. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 5 .
- CHECK IONIZER (ON/OFF) CONTROL SIGNAL CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect ionizer connector.
- Check continuity between A/C auto amp. harness connector and ionizer harness connector.
A/C auto amp. Ionizer Continuity Connector Terminal Connector Terminal M50 38 M119 4 Yes
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair harness or connector.
- CHECK IONIZER (ON/OFF) CONTROL SIGNAL CIRCUIT FOR SHORT
Check continuity between A/C auto amp. harness connector and ground.
A/C auto amp. - Continuity Connector Terminal M50 38 Ground No Is the inspection result normal?
YES
Replace ionizer. Refer to REMOVAL AND INSTALLATION .
NO
Repair harness or connector.