Component Inspection (Front Blower Motor Relay)

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

  1. CHECK BLOWER RELAY

    1. Turn ignition switch OFF.
    2. Remove front blower motor relay.
    3. Check continuity between front blower motor relay terminals 3 and 5 when voltage is supplied between terminals 1 and 2.
      Fig 1: Checking Continuity Between Blower Relay Terminal 3 And 5
      G05915627Courtesy of NISSAN NORTH AMERICA, INC.
      Terminals Voltage Continuity
      3 5 ON Yes
      OFF No

    Is the inspection result normal?

    YES 

    Inspection End.

    NO 

    Replace front blower motor relay.