Diagnostic Test
- CHECK EOP SENSOR POWER SUPPLY - I
- Turn ignition switch OFF.
- Disconnect EOP sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between EOP sensor harness connector terminals.
EOP sensor Voltage
(Approx.)Connector + - terminal F54 3 1 5 V
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
GO TO STEP 4 .
- CHECK EOP SENSOR SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connectors.
- Check the continuity between EOP sensor harness connector and ECM harness connector.
EOP sensor ECM Continuity Connector Terminal Connector Terminal F54 2 F78 14 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace error-detected parts.
- CHECK EOP SENSOR
Check EOP sensor. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Repair or replace error-detected parts.
- CHECK EOP SENSOR POWER SUPPLY - II
Check the voltage between EOP sensor harness connector terminal and ground.
+ - Voltage
(Approx.)EOP sensor Connector Terminal F54 3 Ground 5 V Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 5 .
- CHECK EOP SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connectors.
- Check the continuity between EOP sensor harness connector and ECM harness connector.
EOP sensor ECM Continuity Connector Terminal Connector Terminal F54 3 F78 18 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
Check sensor power supply 2 circuit. Refer to DIAGNOSIS PROCEDURE .
NO
Repair or replace error-detected parts.
- CHECK EOP SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EOP sensor harness connector and ECM harness connector.
EOP sensor ECM Continuity Connector Terminal Connector Terminal F54 1 F78 15 Existed
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace error-detected parts.
- CHECK ECM GROUND CIRCUIT
Check the continuity between ECM harness connector and ground.
ECM - Continuity Connector Terminal E32 147 Ground Existed 149 152 F78 10 55 F79 105 110 Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Repair or replace error-detected parts.