LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 117 (Engine Control System (DTC/Circuit Diagnosis) (VQ35DE) (Except Hybrid) (2 Of 3)) >> DTC/Circuit Diagnosis >> DTC P0447: EVAP Canister Vent Control Valve >> Diagnosis Procedure >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

  1. INSPECTION START

    Will CONSULT be used?

    Will CONSULT be used?

    YES 

    GO TO STEP 2  .

    NO 

    GO TO STEP 3  .

  2. CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT

    G-20With CONSULT 

    1. Turn ignition switch OFF and then ON.
    2. Select "VENT CONTROL/V" in "ACTIVE TEST" mode with CONSULT.
    3. Touch "ON/OFF" on CONSULT screen.
    4. Check for operating sound of the valve.
      Clicking sound should be heard.

    Is the inspection result normal?

    YES 

    GO TO STEP   6  .

    NO 

    GO TO STEP 3  .

  3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY

    1. Turn ignition switch OFF.
    2. Disconnect EVAP canister vent control valve harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between EVAP canister vent control valve harness connector and ground.
      EVAP canister vent control valve Ground Voltage
      Connector Terminal
      B31 1 Ground Battery voltage

    Is the inspection result normal?

    YES 

    GO TO STEP 4  .

    NO 

    Perform the trouble diagnosis for power supply circuit.

  4. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between ECM harness connector and EVAP canister vent control valve harness connector.

      Refer to Wiring Diagram.

      EVAP canister vent control valve ECM Continuity
      Connector Terminal Connector Terminal
      B31 2 E32 141 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES 

    GO TO STEP 5  .

    NO 

    Repair open circuit, short to ground or short to power in harness or connectors.

  5. CHECK RUBBER TUBE FOR CLOGGING

    1. Disconnect rubber tube connected to EVAP canister vent control valve.
    2. Check the rubber tube for clogging.

    Is the inspection result normal?

    YES 

    GO TO STEP 6  .

    NO 

    Clean the rubber tube using an air blower.

  6. CHECK EVAP CANISTER VENT CONTROL VALVE

    Check EVAP canister vent control valve. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Replace EVAP canister vent control valve. Refer to REMOVAL AND INSTALLATION .