Diagnostic Test
- INSPECTION START
Will CONSULT be used?
Will CONSULT be used?
YES
GO TO STEP 2 .
NO
GO TO STEP 3 .
- CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
- Turn ignition switch OFF and then ON.
- Select "VENT CONTROL/V" in "ACTIVE TEST" mode with CONSULT.
- Touch "ON/OFF" on CONSULT screen.
- Check for operating sound of the valve.
Clicking sound should be heard.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 3 .
- CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect EVAP canister vent control valve harness connector.
- Turn ignition switch ON.
- Check the voltage between EVAP canister vent control valve harness connector and ground.
EVAP canister vent control valve Ground Voltage Connector Terminal B31 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Perform the trouble diagnosis for power supply circuit.
- CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and EVAP canister vent control valve harness connector.
Refer to Wiring Diagram.
EVAP canister vent control valve ECM Continuity Connector Terminal Connector Terminal B31 2 E32 141 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK RUBBER TUBE FOR CLOGGING
- Disconnect rubber tube connected to EVAP canister vent control valve.
- Check the rubber tube for clogging.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Clean the rubber tube using an air blower.
- CHECK EVAP CANISTER VENT CONTROL VALVE
Check EVAP canister vent control valve. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace EVAP canister vent control valve. Refer to REMOVAL AND INSTALLATION .