Diagnostic Test
WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.
+ - Voltage (V) Refrigerant pressure sensor Connector Terminal E244 1 Ground Approx. 5
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E244 1 F78 18 Existed Is the inspection result normal?
YES
Check sensor power supply 2 circuit. Refer to DIAGNOSIS PROCEDURE .
NO
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E244 3 F78 25 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace error-detected parts.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E244 2 F78 20 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace error-detected parts.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
Replace refrigerant pressure sensor. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace error-detected parts.