Diagnostic Test
- CHECK ECM POWER SUPPLY
- Turn ignition switch OFF, wait at least 10 seconds and then turn it ON.
- Check the voltage between ECM harness connector terminals.
ECM Voltage Connector Terminal Connector Terminal F79 86 E32 152 Battery voltage
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Refer to DIAGNOSIS PROCEDURE .
- CHECK CONDENSER-1 POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect condenser-1 harness connector.
- Turn ignition switch ON.
- Check the voltage between condenser-1 harness connector and ground.
Condenser-1 Ground Voltage Connector Terminal F21 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- CHECK CONDENSER-1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and condenser-1 harness connector.
IPDM E/R Condenser-1 Continuity Connector Terminal Connector Terminal F19 55 F21 1 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
Refer to DIAGNOSIS PROCEDURE .
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK CONDENSER-1 GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between condenser-1 harness connector and ground.
Condenser-1 Ground Continuity Connector Terminal F21 2 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair open circuit or short to power in harness or connectors.
- CHECK CONDENSER-1
Check condenser-1. Refer to COMPONENT INSPECTION (CONDENSER-1)
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Replace condenser-1.
- CHECK IGNITION COIL POWER SUPPLY
- Reconnect all harness connectors disconnected.
- Disconnect ignition coil harness connector-1.
- Turn ignition switch ON.
- Check the voltage between ignition coil harness connector and ground.
Ignition coil Ground Voltage Cylinder Connector Terminal 1 F47 3 Ground Battery voltage 2 F8 3 3 F48 3 4 F9 3 5 F49 3 6 F10 3
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace harness or connectors.
- CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between ignition coil harness connector and ground.
Ignition coil Ground Continuity Cylinder Connector Terminal 1 F47 2 Ground Existed 2 F8 2 3 F48 2 4 F9 2 5 F49 2 6 F10 2 - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair open circuit or short to power in harness or connectors.
- CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between ignition coil harness connector and ECM harness connector.
Ignition coil ECM Continuity Cylinder Connector Terminal Connector Terminal 1 F47 1 F79 113 Existed 2 F8 1 106 3 F48 1 103 4 F9 1 114 5 F49 1 107 6 F10 1 104 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL WITH POWER TRANSISTOR
Check ignition coil with power transistor. Refer to COMPONENT INSPECTION (IGNITION COIL WITH POWER TRANSISTOR) .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace malfunctioning ignition coil with power transistor. Refer to REMOVAL AND INSTALLATION LH , REMOVAL AND INSTALLATION RH .