Diagnostic Test
- RETIGHTEN A/F SENSOR 1 AND HEATED OXYGEN SENSOR 2
Loosen and retighten the A/F sensor 1 and heated oxygen sensor 2. Refer to REMOVAL AND INSTALLATION (BANK 2) , REMOVAL AND INSTALLATION (BANK 1) .
GO TO STEP 2.
- CHECK FOR EXHAUST GAS LEAK
- Start engine and run it at idle.
- Listen for an exhaust gas leak before the three way catalyst 2.
Is exhaust gas leak detected?
YES
Repair or replace.
NO
GO TO STEP 3 .
- CHECK FOR INTAKE AIR LEAKAGE
- Start engine and run it at idle.
- Listen for an intake air leakage after the mass air flow sensor.
Is intake air leakage detected?
YES
GO TO STEP 4.
NO
Repair or replace malfunctioning part.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to DESCRIPTION .
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected? Is it difficult to start engine?
YES
Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to DTC LOGIC or DTC LOGIC .
NO
GO TO STEP 5.
- CHECK HARNESS CONNECTOR
- Turn ignition switch OFF.
- Disconnect A/F sensor 1 harness connector.
- Check harness connector for water.
Water should not exit.
Is the inspection result normal?
YES
GO TO STEP 6.
NO
Repair or replace harness connector.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.
DTC A/F sensor Ground Voltage (V) Bank Connector Terminal P2096
P20971 F72 1 Ground Battery voltage P2098
P20992 F73 1
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
GO TO STEP 7 .
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between A/F sensor 1 harness connector and IPDM E/R harness connector.
DTC A/F sensor 1 IPDM E/R Continuity Bank Connector Terminal Connector Terminal P2096
P20971 F72 1 F19 52 Existed P2098
P20992 F73 1 53 Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.
DTC A/F sensor 1 ECM Continuity Bank Connector Terminal Connector Terminal P2096
P20971 F72 3 F79 66 Existed 4 67 P2098
P20992 F73 3 76 4 77 - Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.
DTC A/F sensor 1 Ground Continuity Bank Connector Terminal P2096
P20971 F72 3 Ground Not existed 4 P2098
P20992 F73 3 4 DTC ECM Ground Continuity Connector Terminal P2096
P2097F79 66 Ground Not existed 67 P2098
P209976 77 - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK A/F SENSOR 1 HEATER
Check A/F sensor 1 heater. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 10 .
NO
GO TO STEP 12 .
- CHECK HEATED OXYGEN SENSOR 2
Check heated oxygen sensor 2. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
Replace malfunctioning heated oxygen sensor 2.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Perform INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
GO TO STEP 12 .
NO
Repair or replace malfunctioning part.
- REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace malfunctioning air fuel ratio (A/F) sensor 1. Refer to REMOVAL AND INSTALLATION (BANK 2) , REMOVAL AND INSTALLATION (BANK 1) .
Do you have CONSULT?
YES
GO TO STEP 13 .
NO
GO TO STEP 14 .
- CONFIRM A/F ADJUSTMENT DATA
With CONSULT
- Turn ignition switch ON.
- Select "A/F ADJ-B1" and "A/F ADJ-B2" in "DATA MONITOR" mode with CONSULT.
- Make sure that "0.000" is displayed on CONSULT screen.
Is "0.000" displayed?
YES
INSPECTION END
NO
GO TO STEP 14 .
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
Clear the mixture ratio self-learning value. Refer to DESCRIPTION .
Do you have CONSULT?
YES
GO TO STEP 15 .
NO
INSPECTION END
- CONFIRM A/F ADJUSTMENT DATA
With CONSULT
- Turn ignition switch ON.
- Select "A/F ADJ-B1" and "A/F ADJ-B2" in "DATA MONITOR" mode with CONSULT.
- Make sure that "0.000" is displayed on CONSULT screen.
INSPECTION END