Diagnosis Procedure
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect cooling fan control nodule harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control nodule harness connector and ground.
+ - Voltage Cooling fan control module Connector Terminal E225 3 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
GO TO STEP 2 .
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect cooling fan relay harness connector.
- Check the continuity between cooling fan control nodule harness connector and cooling fan relay harness connector.
+ - Continuity Cooling fan control module Cooling fan relay Connector Terminal Connector Terminal E225 3 E82 5 Existed - Also check harness for short to ground.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY POWER SUPPLY CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between cooling fan relay harness connector and IPDM E/R harness connector.
+ - Continuity Cooling fan relay IPDM E/R Connector Terminal Connector Terminal E82 2 E119 27 Existed - Also check harness for short to ground.
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY
Check cooling fan relay. Refer to COMPONENT INSPECTION (COOLING FAN RELAY) .
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Replace cooling fan relay.
- CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan control nodule harness connector and ground.
+ - Continuity Cooling fan control module Connector Terminal E225 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between cooling fan control nodule harness connector and IPDM E/R harness connector.
+ - Continuity Cooling fan control module IPDM E/R Connector Terminal Connector Terminal E225 2 E218 93 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan control module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module terminals and ground.
+ - Voltage Cooling fan control module Connector Terminal E245 4 Ground Battery voltage E246 6
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN MOTORS -1 AND -2
Check the cooling fan motor. Refer to COMPONENT INSPECTION (COOLING FAN MOTOR) .
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace cooling motor. Refer to REMOVAL AND INSTALLATION .