Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK POWER SOURCE (STOP LAMP SWITCH)
- Turn ignition switch OFF.
- Disconnect stop lamp switch connector.
- Check voltage between stop lamp switch connector E38 terminal 1 and ground.
Stop lamp switch Ground Voltage (Approx.) Connector Terminal E38 1 Battery voltage
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Check the following:
- Harness for short or open between fuse block (J/B) and stop lamp switch
- 10A fuse (No. 10, located in fuse block [J/B])
- CHECK STOP LAMP SWITCH
Check stop lamp switch. Refer to COMPONENT INSPECTION (STOP LAMP SWITCH) (RE0F10E) or COMPONENT INSPECTION (STOP LAMP SWITCH) (RE0F10J).
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace stop lamp switch. Refer to EXPLODED VIEW .
- CHECK GROUND CIRCUIT (BCM)
- Disconnect BCM connector M81.
- Check continuity between BCM connector M81 terminals 134, 143 and ground.
BCM Ground Continuity Connector Terminal (+) M81 134 Yes 143
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN BCM AND STOP LAMP SWITCH FOR OPEN
- Disconnect BCM connector M18.
- Check continuity between BCM connector M18 terminal 27 and stop lamp switch connector E38 terminal 2.
BCM Stop lamp switch Continuity Connector Terminal Connector Terminal M18 27 E38 2 Yes
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN BCM AND STOP LAMP SWITCH FOR SHORT CIRCUIT
Check continuity between BCM connector M18 terminal 27 and ground.
BCM Ground Continuity Connector Terminal M18 27 No Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR OPEN
- Disconnect CVT shift selector connector M78 and BCM connector M80.
- Check continuity between BCM connector M80 terminal 108 and CVT shift selector connector M78 terminal 3.
BCM CVT shift selector Continuity Connector Terminal Connector Terminal M80 108 M78 3 Yes
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR SHORT CIRCUIT
Check continuity between BCM connector M80 terminal 108 and ground.
BCM Ground Continuity Connector Terminal M80 108 No Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair or replace damaged parts.
- CHECK GROUND CIRCUIT (CVT SHIFT SELECTOR)
Check continuity between CVT shift selector connector M78 terminal 4 and ground.
CVT shift selector Ground Continuity Connector Terminal M78 4 Yes Is the inspection result normal?
YES
Replace shift lock solenoid. Refer to EXPLODED VIEW (RE0F10E) or EXPLODED VIEW (RE0F10J).
NO
Repair or replace damaged parts.