Diagnosis Procedure
The Signal Tech II Tool [- (J-50190)] can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
- Activate and display TPMS sensor IDs
- Display tire pressure reported by the TPMS sensor
- Read TPMS DTCs
- Register TPMS sensor IDs
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK TIRE PRESSURE SIGNAL
With CONSULT
- Select Data Monitor from AIR PRESSURE MONITOR of BCM.
- Check that the air pressures match the specified value.
Monitor item Displayed value AIR PRESS FL Approximately equal to specified value. Refer to TIRE AIR PRESSURE . AIR PRESS FR AIR PRESS RR AIR PRESS RL
Are all tire pressures displayed 0 kPa (psi)?
YES
GO TO STEP 2.
NO
Replace applicable tire pressure sensor. Refer to REMOVAL AND INSTALLATION .
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER CIRCUIT
Check voltage between remote keyless entry receiver connector M86 terminal 1 and ground.
Remote keyless entry receiver Ground Voltage
(Approx.)Connector Terminal M86 1 - Battery voltage Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair or replace harness or connectors.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL
- Turn ignition switch ON.
- Check signal between remote keyless entry receiver connector M86 terminal 2 and ground with an oscilloscope.
Remote keyless entry receiver Condition Voltage
(Approx.)Connector Terminal M86 2 Standby state When receiving the signal from the transmitter
Is the inspection result normal?
YES
GO TO STEP 6.
NO
GO TO STEP 4.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector M80 and remote keyless entry receiver connector.
- Check continuity between BCM connector M80 terminal 119 and remote keyless entry receiver connector M86 terminal 2.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M80 119 M86 2 Yes - Check continuity between BCM connector M80 terminal 119 and ground.
BCM Ground Continuity Connector Terminal M80 119 - No
Is the inspection result normal?
YES
GO TO STEP 5.
NO
Repair or replace harness or connectors.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between remote keyless entry receiver connector M86 terminal 3 and ground.
Remote keyless entry receiver Ground Continuity Connector Terminal M86 3 - Yes Is the inspection result normal?
YES
Replace the remote keyless entry receiver. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness or connectors.
- TIRE PRESSURE SENSOR ID REGISTRATION
Perform tire pressure sensor ID registration. Refer to WORK PROCEDURE .
Can the tire pressure sensor ID registration be completed?
YES
GO TO STEP 7 .
NO
Replace applicable tire pressure sensor. Refer to REMOVAL AND INSTALLATION .
- RECHECK TIRE PRESSURE SIGNAL
With CONSULT
- Drive at a speed of 40 km/h (25 MPH) or more for 3 minutes, and then drive the vehicle at any speed for 10 minutes.
- Select Data Monitor from AIR PRESSURE MONITOR of BCM.
- Check that the air pressures match the specified value.
Monitor item Displayed value AIR PRESS FL Approximately equal to specified value. Refer to TIRE AIR PRESSURE . AIR PRESS FR AIR PRESS RR AIR PRESS RL
Does Data Monitor display specified value without turning tire pressure warning lamp ON?
YES
Inspection End.
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION .