LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 105 (Defogger (Except Hybrid)) >> DTC/Circuit Diagnosis >> Rear Window Defogger Switch >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

  1. CHECK MULTIFUNCTION SWITCH (REAR WINDOW DEFOGGER SWITCH) CIRCUIT

    Operate the rear window defogger switch.

    Is the inspection result normal?

    YES 

    Inspection End.

    NO 

    GO TO 2.

  2. CHECK MULTIFUNCTION SWITCH (REAR WINDOW DEFOGGER SWITCH) CIRCUIT VOLTAGE

    1. Turn ignition switch ACC.
    2. Check voltage between multifunction switch harness connector M98 terminal 3 and ground.
      (+) (-) Condition Voltage (V)
      (Approx.)
      Multifunction switch
      Connector Terminal
      M98 3 Ground Ignition switch ACC Battery voltage
      OFF 0

    Is the inspection result normal?

    YES 

    Replace multifunction switch. Refer to REMOVAL AND INSTALLATION .

    NO 

    GO TO 3.

  3. CHECK MULTIFUNCTION SWITCH (REAR WINDOW DEFOGGER SWITCH) CIRCUIT FOR OPEN

    1. Turn ignition switch OFF.
    2. Disconnect accessory relay-2 connector E22.
    3. Disconnect multifunction switch connector M98.
    4. Check continuity between multifunction switch connector M98 terminal 3 and accessory relay-2 connector E22 terminal 5.
      Multifunction switch Accessory relay-2 Continuity
      Connector Terminal Connector Terminal
      M98 3 E22 5 Yes

    Is the inspection result normal?

    YES 

    GO TO 4.

    NO 

    Repair and replace harness.

  4. CHECK MULTIFUNCTION SWITCH (REAR WINDOW DEFOGGER SWITCH) CIRCUIT FOR SHORT

    1. Turn ignition switch OFF.
    2. Disconnect accessory relay-2 connector E22.
    3. Disconnect multifunction switch connector M98.
    4. Check continuity between multifunction switch connector M98 terminal 3 and ground.
      Multifunction switch Ground Continuity
      Connector Terminal
      M98 3 No

    Is the inspection result normal?

    YES 

    Check the following:

    • Accessory relay-2.
    • Battery power supply circuit.

    NO 