LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 103 (Interior Lighting System (Except Hybrid)) >> DTC/Circuit Diagnosis >> Interior Room Lamp Control Circuit >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

  1. CHECK INTERIOR ROOM LAMP CONTROL OUTPUT

    G-20 CONSULT

    1. Turn ignition switch ON.
    2. Select INT LAMP of BCM (INT LAMP) active test item.
    3. While operating the test item, check voltage between BCM harness connector M81 terminal 136 and ground.
    BCM Ground Test item Voltage
    (Approx.)
    Connector Terminal
    M81 136 INT LAMP On 0V
    Off Battery voltage

    Is the inspection result normal?

    YES 

    Interior room lamp control circuit is operating normally.

    Fixed ON 

    GO TO STEP 3  .

    Fixed OFF 

    GO TO STEP 2  .

  2. CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
    3. Check continuity between BCM harness connector M81 terminal 136 and front room/map lamp assembly harness connector R107 terminal 7 and cargo lamp harness connector R104 terminal 3.
      BCM Foot lamp Continuity
      Connector Terminal Connector Terminal
      M81 136 Front room/map lamp assembly R107 7 Yes
      Cargo lamp R104 3
    4. Reconnect the front room/map lamp assembly harness connector.
    5. Check continuity between BCM harness connector M81 terminal 136 and personal lamps 2nd row harness connector R106 terminal 3.
      BCM Personal lamps 2nd row Continuity
      Connector Terminal Connector Terminal
      M81 136 R106 3 Yes

    Is the inspection result normal?

    YES 

    Check interior room lamps for an open. If NG, replace lamp in question. Refer to REMOVAL AND INSTALLATION  or REMOVAL AND INSTALLATION  or REMOVAL AND INSTALLATION . If OK, replace BCM. Refer to REMOVAL AND INSTALLATION .

    NO 

    Repair or replace harness or connectors.

  3. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
    3. Check continuity between BCM harness connector M81 terminal 136 and ground.
      BCM Ground Continuity
      Connector Terminal
      M81 136 No

    Is the inspection result normal?

    YES 

    Check interior room lamps for a short circuit. If NG, replace lamp in question. Refer to REMOVAL AND INSTALLATION  or REMOVAL AND INSTALLATION  or REMOVAL AND INSTALLATION . If OK, replace BCM. Refer to REMOVAL AND INSTALLATION .

    NO 

    Repair or replace harness or connectors.