Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
CONSULT
- Turn ignition switch ON.
- Select INT LAMP of BCM (INT LAMP) active test item.
- While operating the test item, check voltage between BCM harness connector M81 terminal 136 and ground.
BCM Ground Test item Voltage
(Approx.)Connector Terminal M81 136 INT LAMP On 0V Off Battery voltage Is the inspection result normal?
YES
Interior room lamp control circuit is operating normally.
Fixed ON
GO TO STEP 3 .
Fixed OFF
GO TO STEP 2 .
- CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
- Check continuity between BCM harness connector M81 terminal 136 and front room/map lamp assembly harness connector R107 terminal 7 and cargo lamp harness connector R104 terminal 3.
BCM Foot lamp Continuity Connector Terminal Connector Terminal M81 136 Front room/map lamp assembly R107 7 Yes Cargo lamp R104 3 - Reconnect the front room/map lamp assembly harness connector.
- Check continuity between BCM harness connector M81 terminal 136 and personal lamps 2nd row harness connector R106 terminal 3.
BCM Personal lamps 2nd row Continuity Connector Terminal Connector Terminal M81 136 R106 3 Yes
Is the inspection result normal?
YES
Check interior room lamps for an open. If NG, replace lamp in question. Refer to REMOVAL AND INSTALLATION or REMOVAL AND INSTALLATION or REMOVAL AND INSTALLATION . If OK, replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness or connectors.
- CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
- Check continuity between BCM harness connector M81 terminal 136 and ground.
BCM Ground Continuity Connector Terminal M81 136 No
Is the inspection result normal?
YES
Check interior room lamps for a short circuit. If NG, replace lamp in question. Refer to REMOVAL AND INSTALLATION or REMOVAL AND INSTALLATION or REMOVAL AND INSTALLATION . If OK, replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness or connectors.