Inspection In Auto Active Test Mode
WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
When auto active test mode is actuated, the following operation sequence is repeated 3 times.
| Operation sequence | Inspection Location | Operation |
|---|---|---|
| 1 | Front wiper | LO for 3 seconds → HI for 3 seconds |
| 2 |
|
10 seconds |
| 3 | Daytime running lamps | 10 seconds |
| 4 | Headlamps | LO => HI 5 times |
| 5 | A/C compressor | ON => OFF 5 times |
| 6* | Cooling fans | LO for 5 seconds → HI for 5 seconds |
* : Outputs duty ratio of 50% for 5 seconds → duty ratio of 100% for 5 seconds on the cooling fan control module.