Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET MAIN SWITCH
- Turn ignition switch OFF.
- Disconnect inverter unit and AC 120 V outlet main switch connectors.
- Check continuity between inverter unit connector B82 terminal 7 and AC 120 V main switch connector M88 terminal 5.
Inverter unit AC 120 V outlet main switch Continuity Connector Terminal Connector Terminal B82 7 M88 5 Yes - Check continuity between inverter unit connector B82 terminal 7 and ground.
Inverter unit Ground Continuity Connector Terminal B82 7 No
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair or replace the harness or connectors.
- CHECK AC 120 V OUTLET MAIN SWITCH GROUND CIRCUIT
Check continuity between AC 120 V outlet main switch connector M88 terminal 6 and ground.
AC 120 V outlet main switch Ground Continuity Connector Terminal M88 6 Yes Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair AC 120 V outlet main switch ground circuit.
- CHECK AC 120 V OUTLET MAIN SWITCH INDICATOR OUTPUT SIGNAL
- Connect AC 120 V outlet main switch and inverter unit connectors.
- Turn ignition switch ON.
- AC 120 V outlet main switch ON.
- Check voltage between the inverter unit connector B82 terminal 7 and ground.
Inverter unit Ground Condition Voltage
(Approx.)Connector Terminal AC 120V outlet main switch B82 7 - OFF 0V ON 5.2V
Is the inspection result normal?
YES
Replace AC 120 V outlet main switch.
NO
Replace inverter unit.