Diagnosis Procedure
- CHECK CONNECTOR
Check combination meter, unified meter and A/C amp. and terminals (combination meter side, unified meter and A/C amp. side, and harness side) for looseness or bent.
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair terminal or connector.
- CHECK CONTINUITY COMMUNICATION CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and unified meter and A/C amp. connector.
- Check continuity between combination meter harness connector terminal and unified meter and A/C amp. harness connector terminal.
Combination meter Unified meter and A/C amp. Continuity Connector Terminals Connector Terminals M53 2 M66 27 Existed 3 7 - Check continuity between combination meter harness connector terminal and ground.
Combination meter Ground Continuity Connector Terminals M53 2 Not existed 3
Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair harness or connector.
- CHECK UNIFIED METER AND A/C AMP. OUTPUT VOLTAGE
- Connect unified meter and A/C amp. connector.
- Turn ignition switch ON.
- Check voltage between unified meter and A/C amp. harness connector terminal and ground.
Terminal Voltage
(Approx.)(+) (-) Unified meter and A/C amp. Connector Terminal M66 27 Ground 5 V
Is the inspection result normal?
YES
GO TO STEP 4.
NO
Replace unified meter and A/C amp.
- CHECK COMBINATION METER OUTPUT VOLTAGE
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector.
- Connect combination meter connector.
- Turn ignition switch ON.
- Check voltage between combination meter harness connector terminal and ground.
Terminal Voltage
(Approx.)(+) (-) Combination meter Connector Terminal M53 3 Ground 5 V
Is the inspection result normal?
YES
INSPECTION END
NO
Replace combination meter.