Diagnostic Test
- CALIBRATION OF DECEL G SENSOR
Perform calibration of decel G sensor. Refer to DESCRIPTION .
GO TO STEP 2 .
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT)
With CONSULT
- Turn the ignition switch OFF → ON.CAUTION:
- Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Start the engine.
- Repeat step 1 two or more times.
- Perform self-diagnosis for "ABS".
Is DTC "C1160" detected?
YES
Replace the ABS actuator and electric unit (control unit). Refer to REMOVAL AND INSTALLATION .
NO
INSPECTION END
- Turn the ignition switch OFF → ON.