Diagnostic Test
- CHECK CONNECTOR
- Turn the ignition switch OFF.
- Check the combination meter harness connector for disconnection or looseness.
- Check the brake fluid level switch harness connector for disconnection or looseness.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair / replace harness or connector, and GO TO STEP 2 .
- PERFORM SELF-DIAGNOSIS (1)
With CONSULT
- Turn the ignition switch OFF → ON.CAUTION:
- Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Start the engine.
- Repeat step 1 two or more times.
- Perform self-diagnosis for "ABS".
Is DTC "C1155" detected?
YES
GO TO STEP 3 .
NO
INSPECTION END
- Turn the ignition switch OFF → ON.
- CHECK BRAKE FLUID LEVEL
- Turn the ignition switch OFF.
- Check the brake fluid level. Refer to INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Refill brake fluid. Refer to REFILLING . GO TO STEP 4 .
- PERFORM SELF-DIAGNOSIS (2)
With CONSULT
- Erase self-diagnosis result for "ABS".
- Turn the ignition switch OFF → ON → OFF.CAUTION:
Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Turn the ignition switch OFF → ON.CAUTION:
- Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Start the engine.
- Repeat step 3 two or more times.
- Perform self-diagnosis for "ABS".
Is DTC "C1155" detected?
YES
GO TO STEP 5 .
NO
INSPECTION END
- CHECK BRAKE FLUID LEVEL SWITCH
Check the brake fluids level switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Replace the reservoir tank. Refer to DISASSEMBLY AND ASSEMBLY . GO TO STEP 6 .
- PERFORM SELF-DIAGNOSIS (3)
With CONSULT
- Erase self-diagnosis result for "ABS".
- Turn the ignition switch OFF → ON → OFF.CAUTION:
Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Turn the ignition switch OFF → ON.CAUTION:
- Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Start the engine.
- Repeat step 3 two or more times.
- Perform self-diagnosis for "ABS".
Is DTC "C1155" detected?
YES
GO TO STEP 7 .
NO
INSPECTION END
- CHECK CONNECTOR AND TERMINAL
- Turn the ignition switch OFF.
- Disconnect brake fluid level switch harness connector.
- Check the brake fluid level switch harness connector for disconnection or looseness.
- Check the brake fluid level switch pin terminals for damage or loose connection with harness connector.
- Disconnect combination meter harness connector.
- Check the combination meter harness connector for disconnection or looseness.
- Check the combination meter pin terminals for damage or loose connection with harness connector.
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
Repair / replace harness, connector, or terminal, and GO TO STEP 8 .
- PERFORM SELF-DIAGNOSIS (4)
With CONSULT
- Erase self-diagnosis result for "ABS".
- Turn the ignition switch OFF → ON → OFF.CAUTION:
Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Turn the ignition switch OFF → ON.CAUTION:
- Be sure to wait of 10 seconds after turning ignition switch OFF or ON.
- Start the engine.
- Repeat step 3 two or more times.
- Perform self-diagnosis for "ABS".
Is DTC "C1155" detected?
YES
GO TO STEP 9 .
NO
INSPECTION END
- CHECK BRAKE FLUID LEVEL SWITCH CIRCUIT
- Turn the ignition switch OFF.
- Disconnect brake fluid level switch harness connector.
- Disconnect combination meter harness connector.
- Check the continuity between brake fluid level switch harness connector and combination meter harness connector.
Brake fluid level switch Combination meter Continuity Connector Terminal Connector Terminal E4 1 M57 25 Existed - Check the continuity between brake fluid level switch harness connector and ground.
Brake fluid level switch - Continuity Connector Terminal E4 1 Ground Not existed
Is the inspection result normal?
YES
GO TO STEP 10 .
NO
Repair / replace harness or connector, and GO TO STEP 10 .
- CHECK BRAKE FLUID LEVEL SWITCH GROUND CIRCUIT
Check the continuity between brake fluid level switch harness connector and ground.
Brake fluid level switch - Continuity Connector Terminal E4 2 Ground Existed Is the inspection result normal?
YES
GO TO STEP 11 .
NO
Repair / replace harness or connector, and GO TO STEP 11 .
- CHECK COMBINATION METER
Check the combination meter. Refer to CONSULT FUNCTION .
Is the inspection result normal?
YES
Replace the ABS actuator and electric unit (control unit). Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace combination meter. Refer to REMOVAL AND INSTALLATION .