Diagnosis Procedure
- CHECK FUSE
Check that the following fuse are not blown.
Signal name Fuse No. Battery power supply 17 Ignition power supply 14 Is the fuse fusing?
YES
Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO
GO TO STEP 2.
- CHECK POWER SUPPLY CIRCUIT
- Turn the ignition switch OFF.
- Disconnect the connector of CAN gateway.
- Check voltage between CAN gateway harness connector and ground.
Terminals Condition Voltage
(Standard)Voltage
(Reference value)(+) (-) CAN gateway Ground Ignition switch Connector Terminal M24 3 OFF 6 - 16 V Battery
voltage9 ON 4.5 - 16 V Battery
voltage
Is the measurement value normal?
YES
GO TO STEP 3.
NO
Repair harness or connector.
- CHECK GROUND CIRCUIT
Check continuity between CAN gateway harness connector and ground.
CAN gateway Ground Continuity Connector Terminal M24 5 Existed 11 Does continuity exist?
YES
INSPECTION END
NO
Repair harness or connector.