Diagnosis Procedure
- CONNECTOR INSPECTION
- Turn the ignition switch OFF.
- Disconnect the battery cable from the negative terminal.
- Disconnect all the unit connectors on CAN communication system.
- Check terminals and connectors for damage, bend and loose connection.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair the terminal and connector.
- CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector terminals.
Data link connector Continuity Connector No. Terminal No. M25 6 14 Not existed Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Check the harness and repair or replace [if shield line or fuse block (J/B) is short] the root cause.
- CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.
Data link connector Ground Continuity Connector No. Terminal No. M25 6 Not existed 14 Not existed Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Check the harness and repair or replace [if shield line or fuse block (J/B) is short] the root cause.
- CHECK ECM AND BCM TERMINATION CIRCUIT
- Remove the ECM and the BCM.
- Check the resistance between the ECM terminals.
ECM Resistance (Ω) Terminal No. 114 113 Approx. 108 - 132 - Check the resistance between the BCM terminals.
BCM Resistance (Ω) Terminal No. 60 59 Approx. 108 - 132
Is the measurement value within the specification?
YES
GO TO STEP 5 .
NO
Replace the ECM and/or the BCM.
- CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.
Inspection result
Reproduced
GO TO STEP 6 .
Non - reproduced
Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
- CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.
- Turn the ignition switch OFF.
- Disconnect the battery cable from the negative terminal.
- Disconnect one of the unit connectors of CAN communication system.NOTE:
ECM and BCM have a termination circuit. Check other units first.
- Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
Reproduced
Connect the connector. Check other units as per the above procedure.
Non - reproduced
Replace the unit whose connector was disconnected.