Diagnosis Procedure
- CONNECTOR INSPECTION
- Turn the ignition switch OFF.
- Disconnect the battery cable from the negative terminal.
- Disconnect all the unit connectors on CAN communication circuit 2.
- Check terminals and connectors for damage, bend and loose connection.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair the terminal and connector.
- CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector terminals.
Data link connector Continuity Connector No. Terminal No. M25 13 12 Not existed Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Check the harness and repair or replace [if shield line or fuse block (J/B) is short] the root cause.
- CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.
Data link connector Ground Continuity Connector No. Terminal No. M25 13 Not existed 12 Not existed Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Check the harness and repair or replace [if shield line or fuse block (J/B) is short] the root cause.
- CHECK CAN GATEWAY TERMINATION CIRCUIT
- Remove the CAN gateway.
- Check the resistance between the CAN gateway terminals.
CAN gateway Resistance (Ω) Terminal No. 4 10 Approx. 108 - 132 6 12 Approx. 108 - 132
Is the measurement value within the specification?
YES
GO TO STEP 5 .
NO
Replace the CAN gateway.
- CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.
Inspection result
Reproduced
GO TO STEP 6 .
Non - reproduced
Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
- CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.
- Turn the ignition switch OFF.
- Disconnect the battery cable from the negative terminal.
- Disconnect one of the unit connectors of CAN communication circuit 2.NOTE:
CAN gateway has two termination circuits. Check other units first.
- Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
Reproduced
Connect the connector. Check other units as per the above procedure.
Non - reproduced
Replace the unit whose connector was disconnected.