Component Inspection
- CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300 Ω) so that the current value becomes about 10 mA. Refer to REMOVAL AND INSTALLATION .
Standard : Approx. 2.5 - 3.0 V Is the measurement value within the specification?
YES
INSPECTION END
NO
Replace Intelligent Key battery.