| Combination meter |
- Displays the shift position on the information display with shift position signal and manual mode indicator signal received from unified meter and A/C amp.
- The combination meter blinks the shift position indicator and sounds a buzzer when received manual mode shift refusal signal from unified meter and A/C amp.
|
| Unified meter and A/C amp. |
- Transmits the signals from the A/T shift selector to TCM with CAN communication line.
- Transmits shift position signal, manual mode indicator signal and manual mode shift refusal signal received from TCM with CAN communication line to the combination meter by means of communication line.
|
| A/T shift selector |
Transmits the following signals to the unified meter and A/C amp. |
|
|
|
- Manual mode shift up signal
|
- Manual mode shift down signal
|
| TCM |
Transmits shift position signal, manual mode indicator signal and manual mode shift refusal signal to the unified meter and A/C amp. |