LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2014 >> QX60 Base, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Power Supply, Ground & Circuit Elements (Except Hybrid) >> Basic Inspection >> Battery >> Work Flow >> Battery Diagnosis Without Exp-800 NI Or Gr8-1200 NI >> Specific Gravity Check

Specific Gravity Check

NOTE: Check the charge condition of the battery.
Periodically check the specific gravity of the electrolyte. Keep a close check on charge condition to prevent over-discharge.
  1. Read hydrometer and thermometer indications at eye level.
  2. Use the chart below to correct your hydrometer reading according to electrolyte temperature.
    Fig 1: Checking Charge Condition Of Battery Using Hydrometer
    G04878548Courtesy of NISSAN NORTH AMERICA, INC.
HYDROMETER TEMPERATURE SPECIFICATION

Battery electrolyte temperature [°C (°F)] Add to specific gravity reading
71 (160) 0.032
66 (150) 0.028
60 (140) 0.024
54 (130) 0.020
49 (120) 0.016
43 (110) 0.012
38 (100) 0.008
32 (90) 0.004
27 (80) 0
21 (70) -0.004
16 (60) -0.008
10 (50) -0.012
4 (40) -0.016
-1 (30) -0.020
-7 (20) -0.024
-12 (10) -0.028
-18 (0) -0.032
Corrected specific gravity Approximate charge condition
1.260 - 1.280 Fully charged
1.230 - 1.250 3/4 charged
1.200 - 1.220 1/2 charged
1.170 - 1.190 1/4 charged
1.140 - 1.160 Almost discharged
1.110 - 1.130 Completely discharged