Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CALIBRATION OF AUTOMATIC BACK DOOR POSITION INFORMATION
- Perform initialization setting of automatic back door position information.
Refer to "WORK PROCEDURE ".
- Erase DTC, and then repeat "PERFORM DTC CONFIRMATION PROCEDURE".
Is DTC detected?
YES: GO TO 2.
NO: Inspection End.
- Perform initialization setting of automatic back door position information.
- CHECK INSTALLATION OF BACK DOOR ASSEMBLY
- Check that back door assembly is installed normally.
Refer to "BACK DOOR ASSEMBLY: ADJUSTMENT ".
- Check back door assembly mechanism deformation, looseness, rattle, interference with other parts and pinched foreign materials.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace the malfunctioning parts.
- Check that back door assembly is installed normally.
- CHECK ENCODER SIGNAL
- Select "AUTOMATIC BACK DOOR CONTROL MODULE" using CONSULT.
- Select "SPINDLE SENSOR LH" and "SPINDLE SENSOR RH" in "DATA MONITOR" mode.
- Check that the function operates normally according to the following conditions.
Monitor item Status SPINDLE SENSOR LH 0 - 65535 SPINDLE SENSOR RH 0 - 65535 Is the difference between the 2 monitor items 10 or more?
YES: GO TO 4.
NO: Replace automatic back door control module. Refer to "REMOVAL AND INSTALLATION ".
- CHECK ENCODER POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect spindle unit connector.
- Check voltage between spindle unit harness connector and ground.
(+) (-) Voltage (Approx.) Spindle unit Connector Terminal LH B70 8 Ground 16.75 - 6 V RH B162 Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- CHECK ENCODER CIRCUIT
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit harness connector.
Automatic back door control module Spindle unit Continuity Connector Terminal Connector Terminal B55 19 LH B70 8 Yes 20 RH B162 - Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B55 19 No 20 Is the inspection result normal?
YES: Replace automatic back door control module. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK ENCODER CIRCUIT 2
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit harness connector.
Automatic back door control module Spindle unit Continuity Connector Terminal Connector Terminal B55 6 LH B70 3 Yes 7 10 8 RH B162 3 9 10 - Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B55 6 No 7 8 9 Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace harness.
- CHECK ENCODER CIRCUIT 3
- Connect automatic back door control module and spindle unit connector
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Voltage (Approx.) Connector Terminal B55 21 0 V Is the inspection result normal?
YES: GO TO 8.
NO: Replace automatic back door control module. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace automatic back door control module. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace the malfunctioning parts.