Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- INSPECTION START
Perform inspection in accordance with procedure that confirms malfunction.
Which procedure confirms malfunction?
Component Function Check 1: GO TO 2.
Component Function Check 2: GO TO 4.
- CHECK HORN FUNCTION
Check that horns function properly using horn switch.
Do horns sound?
YES: GO TO 3.
NO: Check horn circuit. Refer to "WIRING DIAGRAM ".
- CHECK HORN CONTROL CIRCUIT
- Disconnect horn relay.
- Disconnect IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and horn relay harness connector.
IPDM E/R Horn relay Continuity Connector Terminal Connector Terminal E119 23 H1 1 Yes - Check continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E119 23 No
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK ANTI-THEFT HORN RELAY POWER SUPPLY
- Disconnect anti-theft horn relay.
- Check voltage between anti-theft horn relay harness connector and ground.
(+) (-) Voltage (V) Anti-theft horn relay Connector Terminal E8 2 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 5.
NO-1: Check 10 A fuse [No. 57 located in the fuse and fusible link box].
NO-2: Check harness for open or short between anti-theft horn relay and fuse.
- CHECK ANTI THEFT HORN CONTROL CIRCUIT
- Disconnect IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and anti-theft horn relay harness connector.
IPDM E/R Anti theft horn relay Continuity Connector Terminal Connector Terminal E119 22 E8 1 Yes - Check continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E119 22 No
Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness.
- CHECK ANTI-THEFT HORN CIRCUIT
- Check continuity between anti-theft horn relay harness connector and anti-theft horn harness connector.
Anti-theft horn relay Anti-theft horn Continuity Connector Terminal Connector Terminal E8 3 E231 1 Yes - Check continuity between anti-theft horn relay harness connector and ground.
Anti-theft horn relay Ground Continuity Connector Terminal E8 3 No
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace harness.
- Check continuity between anti-theft horn relay harness connector and anti-theft horn harness connector.
- CHECK ANTI-THEFT HORN RELAY
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Replace anti-theft horn.