AROUND VIEW MONITOR CONTROL UNIT: Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK FUSE
Check that the following fuses are not blown.
Terminal No. Signal name Fuse No. 3 Ignition signal 29 (5A) 4 ACC power supply 65 (10A) 2 Battery power supply 15 (15A) Are the fuses blown?
YES: Replace the blown fuse after repairing the affected circuit.
NO: GO TO 2.
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M96.
- Check voltage between around view monitor control unit connector M96 and ground.
Around view monitor control unit Ground Condition Voltage (Approx.) Connector Terminal M96 3 - Ignition switch: ON Battery voltage 4 Ignition switch: ACC 2 Ignition switch: OFF Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness or connectors.
- CHECK GROUND CIRCUIT