Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK CAMERA DATA MONITOR
Check CAMERA IMAGE SIG, CAMERA COMM STATUS and CAMERA COMM LINE for each camera in "DATA MONITOR" of "AVM".
Is "OK" displayed for all cameras?
YES: Refer to "INTERMITTENT INCIDENT ".
NO-1 (LH side camera): GO TO 2.
NO-2 (RH side camera): GO TO 4.
- CHECK LH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and LH side camera connector D20.
- Check continuity between around view monitor control unit connector M97 and LH side camera connector D20.
Around view monitor control unit LH side camera Continuity Connector Terminal Connector Terminal M97 56 D20 6 Yes 58 18 - Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit Ground Continuity Connector Terminal M97 56 - No Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector M97 and LH side camera connector D20.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M97 terminals.
Around view monitor control unit M97 Condition Voltage (Approx.) (+) (-) Terminal Terminal 56 58 CAMERA switch is ON or shift position is R. 6.0 V Is the inspection result normal?
YES: Replace LH side camera. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace around view monitor control unit. Refer to "REMOVAL AND INSTALLATION ".
- CHECK RH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and RH side camera connector D113.
- Check continuity between around view monitor control unit connector M97 and RH side camera connector D113.
Around view monitor control unit RH side camera Continuity Connector Terminal Connector Terminal M97 62 D113 6 Yes 64 18 - Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit Ground Continuity Connector Terminal M97 62 - No Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector M97 and RH side camera connector D113.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M97 terminals.
Around view monitor control unit M97 Condition Voltage (Approx.) (+) (-) Terminal Terminal 62 64 CAMERA switch is ON or shift position is R. 6.0 V Is the inspection result normal?
YES: Replace RH side camera. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace around view monitor control unit. Refer to "REMOVAL AND INSTALLATION ".