Diagnosis Procedure
- CHECK "AUTOMATIC LOCK/UNLOCK SELECT" SETTING IN "WORK SUPPORT"
- Select "DOOR LOCK" of "BCM" using CONSULT.
- Select "AUTOMATIC LOCK/UNLOCK SELECT" in "WORK SUPPORT" mode.
- Check "AUTOMATIC LOCK/UNLOCK SELECT" setting in "WORK SUPPORT".
Refer to "DOOR LOCK: CONSULT FUNCTION (BCM - DOOR LOCK) ".
Is the inspection result normal?
YES: GO TO 2.
NO: Set "Lock Only" or "Lock/Unlock" in "WORK SUPPORT".
- CHECK "AUTOMATIC DOOR LOCK SELECT" SETTING IN "WORK SUPPORT"
- Select "DOOR LOCK" of "BCM" using CONSULT.
- Select "AUTOMATIC DOOR LOCK SELECT" in "WORK SUPPORT" mode.
- Check "AUTOMATIC DOOR LOCK SELECT" setting in "WORK SUPPORT".
Refer to "DOOR LOCK: CONSULT FUNCTION (BCM - DOOR LOCK) ".
Is the inspection result normal?
YES: GO TO 3.
NO: Set "VH SPD" in "AUTOMATIC DOOR LOCK SELECT".
- REPLACE BCM
- Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- Confirm the operation after replacement.
Is the result normal?
YES: Inspection End.
NO: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".