AUTOMATIC BACK DOOR CONTROL UNIT: Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK FUSIBLE LINK
Check that the following fusible link is not open.
Fusible link No. Signal name N (40A) Battery power supply Is the fusible link open?
YES: Replace the open fusible link after repairing the affected circuit.
NO: GO TO 2.
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check voltage between automatic back door control module harness connector and ground.
(+) (-) Voltage Automatic back door control module Connector Terminal B56 25 Ground Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- CHECK GROUND CIRCUIT
Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B56 32 Yes 28 B55 4 (except Mexico) Does continuity exist?
YES: Inspection End.