Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect front door lock assembly LH connector.
- Check voltage between front door lock assembly LH harness connector and ground.
(+) (-) Voltage (Approx.) Front door lock assembly LH Connector Terminal D14 5 Ground 5 V 6 Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK DOOR KEY CYLINDER SWITCH SIGNAL CIRCUIT
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front door lock assembly LH harness connector.
Main power window and door lock/unlock switch Front door lock assembly LH Continuity Connector Terminal Connector Terminal D56 15 D14 6 Yes 16 5 - Check continuity between power window main switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D56 15 No 16 Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK DOOR KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between front door lock assembly LH harness connector and ground.
Front door lock assembly LH Ground Continuity Connector Terminal D14 4 Yes Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace harness.
- CHECK DOOR KEY CYLINDER SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace front door lock assembly LH. Refer to "DOOR LOCK: REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: Inspection End.