Diagnosis Procedure
- CHECK BCM INPUT SIGNAL
Check the BCM input signal. Refer to "COMPONENT FUNCTION CHECK ".
Is the inspection result normal?
YES: GO TO 2.
NO: GO TO 3.
- CHECK COMBINATION METER INPUT SIGNAL
Select the METER/M&A Data Monitor and check the DOOR W/L monitor value.
"DOOR W/L"
Door open: On
Door closed: Off
Is the inspection result normal?
YES: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- CHECK BACK DOOR SWITCH SIGNAL CIRCUIT
Check the back door switch signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK BACK DOOR SWITCH
Perform a unit check for the back door switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Replace back door switch. Refer to "DOOR LOCK: REMOVAL AND INSTALLATION ".