Home >> Infiniti >> 2014 >> Q50 Base, RWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Power Supply, Ground & Circuit Elements (Except Hybrid) >> Basic Inspection >> Battery Inspection >> Work Flow >> Battery Diagnosis Without Exp-800 NI Or Gr8-1200 NI >> Specific Gravity Check

Specific Gravity Check

NOTE: Check the charge condition of the battery.
Periodically check the specific gravity of the electrolyte. Keep a close check on charge condition to prevent over-discharge.
  1. Read hydrometer and thermometer indications at eye level.
  2. Use the chart below to correct your hydrometer reading according to electrolyte temperature.
Fig 1: Checking Battery Specific Gravity Using Hydrometer
G07018397Courtesy of NISSAN NORTH AMERICA, INC.
HYDROMETER TEMPERATURE CORRECTION

Battery electrolyte temperature [°C (°F)] Add to specific gravity reading
71 (160) 0.032
66 (150) 0.028
60 (140) 0.024
54 (130) 0.020
49 (120) 0.016
43 (110) 0.012
38 (100) 0.008
32 (90) 0.004
27 (80) 0
21 (70) -0.004
16 (60) -0.008
10 (50) -0.012
4 (40) -0.016
-1 (30) -0.020
-7 (20) -0.024
-12 (10) -0.028
-18 (0) -0.032
Corrected specific gravity Approximate charge condition
1.260 - 1.280 Fully charged
1.230 - 1.250 3/4 charged
1.200 - 1.220 1/2 charged
1.170 - 1.190 1/4 charged
1.140 - 1.160 Almost discharged
1.110 - 1.130 Completely discharged