Diagnosis Procedure
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Measure voltage between the following terminals of the combination meter.
Combination meter Condition Voltage (Approx.) Connector Terminals (+) (-) M53 7 6 When enter switch is pressed 0 V Other than the above 5 V 8 When select switch is pressed 0 V Other than the above 5 V 9 When illumination control switch (+) is pressed 0 V Other than the above 5 V 10 When illumination control switch (-) is pressed 0 V Other than the above 5 V 11 When trip reset switch is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and meter control switch connector.
- Check continuity between combination meter harness connector and meter control switch harness connector.
Terminals Continuity Combination meter Meter control switch Connector Terminal Connector Terminal M53 6 M54 2 Existed 7 1 8 11 9 6 10 3 11 12 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M53 6 Not existed 7 8 9 10 11 Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.