Component Inspection
- CHECK METER CONTROL SWITCH
- Turn ignition switch OFF.
- Disconnect meter control switch connector.
- Check meter control switch.
Meter control switch Condition Continuity Terminals 1 2 When illumination control switch (-) is pressed Yes Other than the above No 3 When trip reset switch is pressed Yes Other than the above No 12 When illumination control switch (+) is pressed Yes Other than the above No Is the inspection result normal?
YES: Inspection End.
NO: Replace meter control switch. Refer to "REMOVAL AND INSTALLATION ".