Component Inspection
- CHECK TRUNK ROOM LAMP SWITCH
- Turn ignition switch OFF.
- Disconnect trunk room lamp switch connector.
- Check continuity between trunk room lamp switch terminals.
Trunk room lamp switch Condition Continuity Terminal 1 2 Trunk lid lock assembly Unlocked Existed Locked Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace trunk room lamp switch (trunk lid lock assembly). Refer to "TRUNK LID LOCK: REMOVAL AND INSTALLATION ".