Component Function Check
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Connect the CONSULT.
- Select the "Data Monitor" for the "METER/M&A" and check the "PKB SW" monitor value.
"PKB SW"
Parking brake is applied: On
Parking brake is released: Off
: INSPECTION END